1.
International Journal of Intelligent Unmanned Systems ; 2022.
Article in English | Web of Science | ID: covidwho-1997105

ABSTRACT

Purpose In the COVID-19 outbreak periods, people's life has been deranged, leading to disrupt the world. Firstly, the number of deaths is growing and has the potential to surpass the highest level at any time. Secondly, the pandemic broke many countries' fortified lines of epidemic prevention and gave people a more honest view of its seriousness. Finally, the pandemic has an impact on life, and the economy led to a shortage in medical, including a lack of clinicians, facilities and medical equipment. One of those, a simple ventilator is a necessary piece of medical equipment since it might be useful for a COVID-19 patient's treatment. In some cases, the COVID-19 patients require to be treated by modern ventilators to reduce lung damage. Therefore, the addition of simple ventilators is a necessity to relieve high work pressure on medical bureaucracies. Some low-income countries aim to build a simple ventilator for primary care and palliative care using locally accessible and low-cost components. One of the simple principles for producing airflow is to squeeze an artificial manual breathing unit (AMBU) iterative with grippers, which imitates the motion of human fingers. Unfortunately, the squeezing angle of grippers is not proportional to the exhaust air volume from the AMBU bag. This paper aims to model the AMBU bag by a mathematical equation that enables to implement on a simple controller to operate a bag-valve-mask (BVM) ventilator with high accuracy performance. Design/methodology/approach This paper provides a curvature function to estimate the air volume exhausting from the AMBU bag. Since the determination of the curvature function is sophisticated, the coefficients of the curvature function are approximated by a quadratic function through the experimental identification method. To obtain the high accuracy performance, a linear regression model and a least square method are employed to investigate the characteristic of the BVM ventilator's grippers angle with respect to the airflow volume produced by the AMBU bag. Findings This paper investigates the correlation between the exhausting airflow of the AMBU bag and the grippers angle of the BVM ventilator. Originality/value The experimental results validated that the regression model of the characteristic of the exhausting airflow of the AMBU bag with respect to the grippers' angle has been fitted with a coefficient over 98% within the range of 350-750 ml.

2.
Aims Bioengineering ; 8(3):192-207, 2021.
Article in English | Web of Science | ID: covidwho-1310150

ABSTRACT

Ventilators are drawn to many researchers during the Covid-19 pandemic because it's essential equipment that's accustomed to treat severe Covid-19 patients. In low-income countries, there's a shortage of pricy respiratory devices resulting in exceeding the provision of taking care of Covid-19's patients in ICU. This paper attempts to design and implement an appropriate respiratory device referred to as a bag valve mask (BVM) ventilator for those who are Covid-19 patients in medical care, those patients have a requirement of safe transport and also palliative care. The BVM ventilator comprises a man-made manual breath unit (AMBU) bag and paddles for squeezing the AMBU bag which is popular in medical aid settings. The BVM ventilator is required to travel airflow through the system to the patient's lung with the specified volume for every breath cycle within a threshold air pressure. Since the AMBU bag is straightforward to be deformed over time, it's difficult to get mathematical modelling for constructing a reliable controller. Therefore, a model-free control (MFC) control approach is utilized successfully to style a controller for our BVM ventilator model with a PEEP valve and a HEPA filter. Some experimental scenarios are administered to gauge the effectiveness of the proposed controller for the BVM ventilator to control the airflow and control air pressure mode.

SELECTION OF CITATIONS
SEARCH DETAIL